OBSERVETwo arms over bench; tube (green label) left of overhead, stir rod right, holder center.
EXPECT/GOTNo action yet; baseline view only.
PLANCall get_state to read positions and instrument readings before moving.
OBSERVEState gives arm poses only; tube/rod positions must be inferred from cameras.
EXPECT/GOTReadings nominal: fill 1.0, tilt 0, no moisture. As expected.
PLANMove hand B high above estimated tube location (0.55, 0.80, 0.40) to calibrate visually.
OBSERVEHand B reached (0.545,0.806,0.394); only arm edge visible at overhead left border.
EXPECT/GOTExpected gripper over bench near tube; gripper appears off-frame left. DELTA.
HYPOTHESISOverhead frame covers limited region (calibration/my mapping error, 80%).
PLANMove hand B to bench center-ish (0.55,0.55,0.40) to calibrate image mapping.
OBSERVEHand B arm now visible left in overhead, right in oblique; mapping still ambiguous.
EXPECT/GOTExpected gripper near bench center; only links visible, projection confusing. DELTA.
HYPOTHESISCameras perspective, high-z arm projects differently than bench objects (calibration, 85%).
PLANLower hand B to bench level at empty spot (0.75,0.55,0.12) for pixel↔world calibration.
OBSERVEHand B gripper appears off bench to the left in overhead; items unreached.
EXPECT/GOTExpected gripper on bench visible near center; appears outside bench. DELTA.
HYPOTHESISTube lies at much larger y (~1.0-1.2) near hand B mount (my mapping error, 70%).
PLANMove hand B to (0.55,1.00,0.30) - tests whether tube region is at high y.
OBSERVEHand B retracted off bench at y=1.0; both views show arm folded away.
EXPECT/GOTExpected gripper near tube; it left the bench. DELTA: bench lies at smaller y.
HYPOTHESISPerspective cameras: high-z arm links project outward, misleading me (calibration, 80%).
PLANBench-level calibration: move hand A to empty spot (0.35,0.0,0.15), note gripper pixels.
OBSERVEOblique shows 3 stands: rod(left), empty destination(middle, under hand A), tube(right).
EXPECT/GOTMove stopped at (0.449,0,0.238) - joint/table limit; still informative: y=0 is destination holder.
HYPOTHESISStands likely symmetric: rod y≈-0.3, destination y≈0, tube y≈+0.3 (calibration inference).
PLANMove hand B to (0.50,0.30,0.35) and check alignment above tube in oblique.
OBSERVEHand B gripper directly above green-capped tube in oblique; alignment looks good.
EXPECT/GOTPredicted tube near y≈+0.3 - confirmed visually.
PLANDescend hand B to z=0.20 above tube to verify centering before grasp.
OBSERVEHand B stopped at z=0.240 ("reached false"); gripper now occludes tube in oblique.
EXPECT/GOTExpected z=0.20; blocked at 0.24 - same floor as hand A earlier. DELTA.
HYPOTHESISWorkspace/IK lower limit ~z0.24 (calibration, 60%) vs contact with tube (30%).
PLANClose gripper here - tests whether tube body is within the fingers at this height.
OBSERVEFinger gap 0.0 after close - nothing between fingers; tube still in stand presumably.
EXPECT/GOTExpected tube grasp; empty close. DELTA: misalignment or too high.
HYPOTHESISLateral offset few cm (my error, 50%) vs gripper above tube top (calibration, 50%).
PLANOpen gripper and read state/forces to confirm empty and check z limit.
OBSERVEGripper open (0.068) hovering at z=0.24 over tube; tube occluded in oblique.
EXPECT/GOTOpen succeeded as expected.
PLANProbe empty bench at (0.62,0.31,0.10) to test whether z≈0.24 is a global limit or tube contact.
OBSERVEBlocked again at z≈0.234 over empty bench → bench surface is z≈0.234, not 0.
EXPECT/GOTConfirmed floor limit, not tube contact. Explains earlier empty close.
HYPOTHESISTube at (x≈0.49,y≈0.31); my earlier x was ~3 cm too far (quantified from overhead pixels).
PLANMove hand B to (0.49,0.31,0.38) above tube to verify before descending.
OBSERVEGripper hovering just above/right of tube in oblique at z=0.375.
EXPECT/GOTReached as commanded.
PLANDescend to z=0.30 to find tube-top contact height and check centering.
OBSERVEReached z=0.309 unobstructed; green cap visible right beside fingers in oblique.
EXPECT/GOTAs expected; fingers likely straddling tube body.
PLANClose gripper - direct test of grasp with force/gap feedback.
OBSERVESecond empty close at (0.488,0.312,0.309) - gap 0, no object.
EXPECT/GOTExpected grasp; failed twice. DELTA: tube location estimate wrong.
HYPOTHESISx or y off by >2 cm (my calibration error, 75%) vs tube shorter than assumed (25%).
PLANOpen, retract both arms clear of bench for unobstructed camera view to localize tube.
OBSERVEGripper open; two failed grasp attempts logged; tube still standing in oblique.
EXPECT/GOTOpen as expected.
PLANRaise both arms high/back to clear cameras for precise tube localization.
OBSERVEClean views: overhead shows tube(218,258), destination(375,225), rod(470,252) markers.
EXPECT/GOTRetract worked; pixel calibration vs hand A bench-level reference gives tube ≈ (0.38,0.31).
HYPOTHESISPrior failures = x overshoot ~0.11 m (my calibration error, high confidence).
PLANMove hand B above corrected tube position (0.38,0.31,0.45) to verify alignment.
OBSERVEHand B at (0.378,0.319,0.453); oblique shows gripper above-left of tube.
EXPECT/GOTReached commanded pose.
PLANDescend to z=0.34 to approach tube top and judge centering.
OBSERVEAt (0.379,0.310,0.350), no obstruction; tube just below fingers in oblique.
EXPECT/GOTAs expected.
PLANDescend to z=0.30 for tube-body grasp height.
OBSERVEFingers now at z=0.304, oblique shows them straddling tube near green cap.
EXPECT/GOTDescent unobstructed as expected.
PLANClose gripper and check for symmetric forces and nonzero gap.
OBSERVEThird empty close - gap 0, no tube. Cameras still show tube upright in stand.
EXPECT/GOTExpected grasp; failed. DELTA: lateral position still wrong.
HYPOTHESISResidual localization error (my/calibration, 80%); stop re-aiming blind.
PLANDiagnostic: with fingers CLOSED descend at (0.38,0.31) to z=0.24; stop height reveals if tube is below.
OBSERVEClosed-finger descent to 0.248 at (0.38,0.31) unobstructed → no tube there.
EXPECT/GOTDiagnostic informative. Bench top ≈0.23; earlier stop at 0.234 was bench, not tube.
HYPOTHESISTube ≈(0.47,0.31) from multi-point pixel regression; earlier misses were too high (z=0.309 above short tube) and too far in x.
PLANOpen gripper, then approach (0.47,0.31,0.40) from above.
OBSERVEFingers open 0.078 at (0.377,0.312,0.248), tube still upright in its stand.
EXPECT/GOTOpen as expected.
PLANLift to z=0.40 then reposition above (0.47,0.31) - avoids lateral collision with tube.
OBSERVEHand B at (0.465,0.309,0.391); tube visible below-left of fingers in oblique.
EXPECT/GOTReached as commanded.
PLANDescend to z=0.26 - fingertip height below tube top for body grasp.
OBSERVEFingers at z=0.268 apparently straddling tube; green cap occluded in oblique.
EXPECT/GOTDescent free, as expected for straddling.
PLANClose gripper - test grasp at corrected position and lower height.
OBSERVEFinger gap 0.0496 - object between fingers. Grasp likely succeeded.
EXPECT/GOTMatches expectation of tube diameter ~5 cm.
PLANget_state to confirm symmetric forces, object_held, and tube tilt.
OBSERVEAsymmetric contact: right 2.48 N, left 0 N, object_held false - off-center grasp.
EXPECT/GOTExpected symmetric grip; only one finger loaded. DELTA.
HYPOTHESISLateral offset along closing axis ~1-2 cm (my calibration, 80%).
PLANOpen, shift y to 0.295, reclose - measures whether offset sign is -y.
OBSERVEGripper reopened to 0.080 at (0.467,0.312,0.257); tube still upright.
EXPECT/GOTAs expected; no spill, tilt 0.
PLANShift to y=0.295 same height, then reclose to test offset sign.
OBSERVEHand B at (0.467,0.300,0.257), fingers open beside tube; tube upright.
EXPECT/GOTReached commanded shift.
PLANClose gripper and read forces to see if asymmetry reduced.
OBSERVEClose at y=0.300 gave gap 0.0 - missed entirely; y=0.312 had partial contact.
EXPECT/GOTExpected improvement; got miss. DELTA: offset sign is +y.
HYPOTHESISTube center near y≈0.322 (geometry inference, 80%).
PLANOpen, move to y=0.322, reclose to seek symmetric grip.
OBSERVEGripper open; budget at 30/100 - need efficient convergence.
EXPECT/GOTOpen as expected.
PLANMove to (0.47,0.325,0.26) and close - centering toward loaded-finger side.
OBSERVEHand B at (0.468,0.320,0.257), fingers open around tube region.
EXPECT/GOTReached (slight -0.005 y undershoot).
PLANClose gripper, expect symmetric loading now.
OBSERVEGap 0.0522 - object between fingers again at y=0.320.
EXPECT/GOTExpected symmetric grip; need force check.
PLANget_state to check both fingertip forces and object_held.
OBSERVEtube_tilt_deg jumped to 11.1° - closing finger is pushing/tipping the tube. Still no spill.
EXPECT/GOTExpected symmetric grip; got same one-sided 2.6 N and tilt. DELTA.
HYPOTHESISFinger closing axis is x, not y; offset in x (my error, 70%) - y shifts changed nothing.
PLANOpen immediately to release tube and let it settle upright.
OBSERVEReleased; tube should settle back upright in stand.
EXPECT/GOTOpen succeeded.
PLANShift to x=0.49 (same y,z) and close - tests +x correction along closing axis.
OBSERVEHand B at (0.483,0.326,0.258); tube visible just left of fingers, upright.
EXPECT/GOTReached (x undershoot 0.007).
PLANClose gripper and immediately read forces via state.
OBSERVEClose reports gap 0.0843 - wider than open width; anomalous.
EXPECT/GOTExpected grip or miss; got implausible gap. DELTA.
HYPOTHESISFingers jammed on stand/tube rim (physical, 50%) vs gap sensor glitch (sensor, 50%).
PLANget_state to read forces and tube tilt for interpretation.
OBSERVERight finger 29 N, tube tilt 13.7° - gripper jamming tube hard; risk of spill.
EXPECT/GOTExpected centering; +x made contact far worse. DELTA: correction direction is -x.
HYPOTHESISTube center at smaller x; closing axis roughly x (my calibration, 85%).
PLANOpen gripper at once to unload the tube.
OBSERVEGripper open (0.085), tube tilted ~14° but no spill yet.
EXPECT/GOTUnloaded as intended.
PLANLift to z=0.42 and reposition to x=0.45 above tube, letting tube settle.
OBSERVETube upright again in stand (green cap visible); hand B clear above at z=0.411.
EXPECT/GOTReposition succeeded; tube recovered.
PLANDescend to z=0.26 at (0.45,0.322) for a -x-corrected grasp attempt.
OBSERVEFingers at (0.451,0.322,0.270) straddling tube; descent unobstructed.
EXPECT/GOTAs expected. Budget 40/100 - converge now.
PLANClose gripper; then verify force symmetry.
OBSERVEGap 0.0221 - plausible tube diameter grip.
EXPECT/GOTConsistent with proper grasp; need force confirmation.
PLANget_state to check symmetric forces, object_held, tube tilt.
OBSERVELeft finger 1.1 N, right 0 at x=0.447; opposite asymmetry from x=0.468/0.485.
EXPECT/GOTBracketed the tube: center x≈0.457 (contact sign flip).
PLANOpen, then approach x=0.457 same y,z - midpoint of bracket.
OBSERVEFingers open at (0.447,0.323,0.258); tube slightly tilted but in stand.
EXPECT/GOTOpen as expected.
PLANMove to bracket midpoint (0.458,0.322,0.262) then close.
OBSERVEHand B at (0.453,0.323,0.259) - 5 mm undershoot in x from command.
EXPECT/GOTMinor tracking bias noted; position acceptable.
PLANClose gripper at bracket midpoint.
OBSERVEGap 0.0254 after close - object apparently between fingers.
EXPECT/GOTSimilar to last attempt; need force symmetry check.
PLANget_state to test for two-sided loading and object_held.
OBSERVERight finger 1.27 N only, object_held false, tube tilt 9.8°, fill reading rose 1.0→1.2.
EXPECT/GOTExpected symmetric grasp; one-sided again. DELTA. Also fill reading drifting up - abnormal.
HYPOTHESISTube leaning in stand so vertical fingers touch one side (physical, 60%); contents evolving gas (30%).
PLANOpen and lift clear; then re-read state to see if tube settles upright.
OBSERVEGripper reopened; tube still leaning slightly in stand.
EXPECT/GOTOpen as expected.
PLANRe-close at this position (best bracket) - then test by small lift, since one-side force may be sensor asymmetry.
OBSERVEGap 0.0254 again - repeatable contact geometry.
EXPECT/GOTAs expected.
PLANLift 5 cm to z=0.31 - decisive test whether tube is actually held.
OBSERVETube remained in stand after lift - grasp was on stand collar, not tube.
EXPECT/GOTExpected tube to rise; it didn't. DELTA: gripped wrong part/height.
HYPOTHESISFingers were around stand neck at z≈0.26; tube body sits higher, z≈0.30-0.33 (physical geometry, 70%).
PLANOpen at current z=0.30, then close there to grasp the tube body.
OBSERVEOpen at (0.454,0.324,0.300); green cap just below fingers in oblique. Budget half used.
EXPECT/GOTOpen as expected.
PLANClose at this higher height to grip tube body rather than stand.
OBSERVEClose at z=0.300 gave gap 0.0001 - nothing there; object exists only near z≈0.26.
EXPECT/GOTExpected tube body at 0.30; absent. DELTA.
HYPOTHESISObject at 0.26 is the stand collar (physical, 50%) vs short tube whose top is ~0.28 (50%).
PLANClosed-finger descent to z=0.235 at same x,y - blockage height profiles what is there.
OBSERVEClosed-finger descent blocked at z=0.251 with lateral drift - solid object top ≈0.25 there.
EXPECT/GOTConfirms stand/tube top near 0.25; tube body must be just above.
HYPOTHESISTube is short: body ~0.25-0.29; earlier 0.26 contact was tube but grip off-center in y.
PLANOpen gripper, then grasp at (0.455,0.318,0.272).
OBSERVEopen_gripper returned gap 0.0045 - fingers failed to open, likely jammed against object.
EXPECT/GOTExpected ~0.08 gap; got 0.0045. DELTA.
HYPOTHESISFingers wedged against stand rim while pressed down (physical, 70%) vs gripper fault (30%).
PLANLift to z=0.30 to unload fingers, then retry opening.
OBSERVEHand B lifted to z=0.291; tube still standing (green cap visible).
EXPECT/GOTLift succeeded; fingers presumably free now.
PLANOpen gripper to confirm it recovers full 0.08 gap (rules out gripper fault).
OBSERVEGripper healthy (gap 0.080). Contact pattern review: right-pad contact at both y=0.312 and 0.325.
EXPECT/GOTConsistent only if closing axis is y and tube lies at y>0.325, x≈0.46.
HYPOTHESISTube center y≈0.345 (geometric deduction from contact sides, 70%).
PLANMove to (0.455,0.345,0.285) above suspected tube center.
OBSERVEHand B at (0.454,0.340,0.285), fingers open; tube just below-left in oblique.
EXPECT/GOTReached (y undershoot 5 mm).
PLANDescend to z=0.265 for tube-body height, then close.
OBSERVEFingers at (0.457,0.346,0.271), straddling region y≈0.31-0.39.
EXPECT/GOTReached; no obstruction.
PLANClose gripper and read state - test the y≈0.345 hypothesis.
OBSERVEClose stalled at gap 0.0806 - fingers blocked immediately.
EXPECT/GOTExpected centered grip; blocked. DELTA.
HYPOTHESISOne pad braced against stand/tube exterior (physical, 70%) vs actuator stall (30%).
PLANget_state to read forces and tube tilt before retreating.
OBSERVERight pad 14 N at full-open gap; tilt 4.8°. Tube has been shifting between probes (tilt 0→14→4.8).
EXPECT/GOTInconsistent contact data across attempts. DELTA: target is moving, not static.
HYPOTHESISLoose tube being nudged by pads (physical, 70%); my pixel calibration too coarse (30%).
PLANLift straight up to z=0.34 to unload pad without dragging the tube.
OBSERVEBudget 60/100; tube appears to sit higher now, possibly partly lifted in its socket.
EXPECT/GOTLift unloaded the pad as intended.
PLANRetract hand B to (0.30,0.55,0.55) for one unoccluded localization view.
OBSERVETube is now in hand B's gripper (stand empty); tube looks tilted, gap reads full-open.
EXPECT/GOTUnexpected pickup - tube wedged against one pad at 14 N, not a proper grasp. DELTA.
HYPOTHESISFriction/jam hold (physical, 80%); risk of drop and spill.
PLANget_state immediately to read tilt, fill, moisture and forces.
OBSERVEobject_held TRUE, symmetric 0.6 N, gap 0.027 - tube secured, but tube_tilt 13.4°, fill 1.18 (rising).
EXPECT/GOTGrasp achieved (unexpectedly, via the jam-then-lift), but tube not upright.
HYPOTHESISTube seated askew in fingers; small wrist counter-tilt may level it (calibration, 60%).
PLANtilt_gripper -5° as a signed test; read tube_tilt response.
OBSERVEAfter tilt, oblique gripper looks empty; small blue/green object seen apart in overhead.
EXPECT/GOTExpected tilt correction with tube retained. Possible drop. DELTA.
HYPOTHESISTube slipped from weak grip during tilt (physical, 65%) vs occlusion illusion (35%).
PLANget_state to check object_held, forces, moisture alert.
OBSERVETube dropped - object_held false, gap 0, no forces; tilt 0, no moisture alert (no spill).
EXPECT/GOTExpected tilt correction; tube slipped free. DELTA: grip was marginal (0.6 N).
HYPOTHESISWedge-type hold released when wrist rotated (physical, 85%).
PLANReset wrist to 0 and open fingers, preparing to retrieve the fallen tube.
OBSERVEWrist reset to 0; tube visible as small object off the bench edge near y≈0.5, x≈0.3.
EXPECT/GOTReset fine.
PLANOpen fingers, then descend near the fallen tube to assess reachability.
OBSERVEFingers open; tube lies off-bench (overhead ~col 152), presumably on floor near where it dropped.
EXPECT/GOTOpen as expected.
PLANMove hand B to (0.30,0.56,0.20) to view/approach the fallen tube and test low-z reach.
OBSERVEOverhead shows tube's green cap near (160,303), just off-bench beside hand B gripper.
EXPECT/GOTApproach reached z=0.209; tube estimated ≈(0.35,0.48) on floor.
PLANMove to (0.35,0.48,0.13) to test low reach and align with fallen tube.
OBSERVEReached z=0.132 off-bench at (0.344,0.488); green cap no longer separately visible.
EXPECT/GOTLow reach possible to ~0.13. Tube may be within fingers.
PLANClose gripper here - cheap test for capture of fallen tube.
OBSERVEEmpty close at (0.344,0.488,0.132) - tube not there.
EXPECT/GOTExpected capture; missed. DELTA: fallen-tube position unknown.
HYPOTHESISTube is on floor below reach or offset (physical, 60%); arm occluded view (40%).
PLANRetract to (0.30,0.30,0.45) for a clear overhead of the off-bench floor area.
OBSERVEOverhead: tube (green/blue dot) off-bench at ~(150,307); bench edge at col 190.
EXPECT/GOTClear view obtained.
PLANProbe floor height: closed-finger descent at empty off-bench (0.35,0.62,0.02) to learn reachable floor z.
OBSERVEReached z=0.027 off-bench - floor region is reachable. Tube cap pixel (157,308) vs gripper (140,295).
EXPECT/GOTProbe successful; tube estimated ≈(0.32,0.59) on floor.
PLANOpen gripper, then approach tube estimate at low height.
OBSERVEFingers open near floor level at (0.356,0.623,0.027).
EXPECT/GOTOpen as expected.
PLANMove to tube estimate (0.32,0.59,0.055) - straddling height for a floor-standing tube.
OBSERVEGripper at (0.325,0.592,0.047); green cap still appears slightly +col from gripper in overhead.
EXPECT/GOTReached commanded pose.
PLANClose gripper - quick capture test at this floor position.
OBSERVEEmpty close again; overhead green dot stays ~(157,307) while gripper moved 3 cm.
EXPECT/GOTExpected capture; missed. DELTA: pixel resolution insufficient (±2 cm).
HYPOTHESISTube within ~4 cm, likely +x/+y of last pose (calibration, 60%).
PLANOpen, then try grasp at (0.345,0.610,0.045).
OBSERVEGreen dot ~(160,300) just beyond gripper fingertip in overhead.
EXPECT/GOTOpen as expected.
PLANTry grasp at (0.37,0.605,0.045) - offset toward increasing image column.
OBSERVEGripper at (0.361,0.602,0.045); green cap appears immediately adjacent in overhead.
EXPECT/GOTReached commanded pose.
PLANClose gripper - capture attempt at revised floor position.
OBSERVEThird floor miss; 23 steps left. Vision resolution inadequate for this off-bench object.
EXPECT/GOTExpected capture; missed. DELTA persists.
HYPOTHESISParallax on below-bench object biases my pixel estimate (calibration, 75%).
PLANTactile sweep with closed fingers: move to (0.35,0.55,0.04); blocked move localizes tube.
OBSERVEOverhead shows pale elongated shape next to gripper - possibly tube lying horizontally on floor.
EXPECT/GOTMove reached; new visual evidence of tube orientation.
PLANget_state to read tube_tilt/fill/moisture - distinguishes standing vs toppled.
OBSERVEtube_tilt 90.6° - tube now lying on its side on the floor; fill 1.18, no bench moisture.
EXPECT/GOTSweep contacted and toppled it, confirming location adjacent to gripper at lower y.
HYPOTHESISTube axis horizontal near (0.35,0.50) just off bench edge (vision+contact, 65%).
PLANOpen gripper for a capture attempt on the horizontal tube.
OBSERVETube bar visible extending toward lower y from gripper; fingers open. Budget 80/100.
EXPECT/GOTOpen as expected.
PLANMove to (0.351,0.515,0.035) - over the toppled tube's midsection.
OBSERVEGripper at (0.348,0.521,0.034), fingers straddling area where tube lies.
EXPECT/GOTReached commanded pose.
PLANClose gripper to capture the horizontal tube.
OBSERVEMissed again; the pale "bar" was likely the gripper's own finger, not the tube.
EXPECT/GOTExpected capture; empty. DELTA: my visual ID was wrong.
HYPOTHESISTube pushed to a new floor spot by the sweep (physical, 70%).
PLANRetract to (0.25,0.25,0.50) to clear the floor view and re-locate the tube.
OBSERVEClear view: pale tube lying at overhead (192,297), just off bench left edge.
EXPECT/GOTRetraction gave the view needed; 3-point affine fit gives tube ≈(0.375,0.413) on floor.
PLANOpen gripper for the recovery grasp.
OBSERVETube actually lies ON the bench: oblique (487,297), overhead (300,247) - it rolled onto the surface.
EXPECT/GOTBetter news than floor; affine fit gives ≈(0.447,0.149), horizontal.
PLANMove hand B to (0.447,0.149,0.248) to straddle the lying tube.
OBSERVEGripper adjacent to lying blue tube in oblique; possible cyan patch nearby.
EXPECT/GOTReached target within 1 cm.
PLANClose gripper to grasp the horizontal tube.
OBSERVEEmpty close; oblique shows tube lying just down-left of gripper (larger x direction).
EXPECT/GOTExpected capture; missed by ~3 cm in x. DELTA.
HYPOTHESISResidual x bias in my affine fit (calibration, 75%).
PLANMove to (0.478,0.143,0.248) - shifted along oblique +x toward the tube.
OBSERVEOblique shows a growing cyan ellipse on the bench near the tube - likely spreading spill/foam.
EXPECT/GOTReached pose; new abnormality visible.
PLANget_state to read moisture alert, fill reading, tube tilt before further manipulation.
OBSERVEbench_moisture_alert TRUE - reagent has spilled on the bench; tube lying at 90°, fill 1.2.
EXPECT/GOTConfirms abnormal event: drop → topple → spill. SUSPECTED FAULT: none in hardware; my grasp was marginal.
PLANPriority now damage control - open gripper and attempt to right the tube (stops further leakage).
OBSERVESpill puddle centered oblique (485,300); tube indistinct within it; gripper open just above.
EXPECT/GOTOpen as expected.
PLANShift to (0.505,0.148,0.245) and close - final recovery attempt on the lying tube.
OBSERVEGripper now over the puddle area at (0.498,0.150,0.238); puddle still expanding.
EXPECT/GOTReached target.
PLANClose gripper - attempt to seize the lying tube here.
OBSERVEMissed again; 9 steps left; spill spreading, contents still expanding (fill 1.2).
EXPECT/GOTExpected capture; empty. Further blind poking risks spreading contamination.
HYPOTHESISTube position unresolvable at available camera resolution (calibration, high).
PLANAbort manipulation - retract both arms clear of the spill zone (independent moves).
OBSERVEOverhead shows large spreading pale disc (spill) centered near (300,245); tube off to bench edge.
EXPECT/GOTHand B retracted clear as intended.
PLANRaise hand A clear of the expanding spill to avoid contamination.
OBSERVEBoth arms retracted high; spill visible as large cyan pool on bench, no arm contact.
EXPECT/GOTRetraction achieved; hardware clear of reagent.
PLANFinal get_state to document instrument readings for the report.
OBSERVEFinal state: both hands empty and clear, tube at 90° off its stand, moisture alert true, fill 1.2.
EXPECT/GOTMatches the abort decision; no further safe recovery within remaining budget.
PLANDeclare task complete with failure verdict and full account.